首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Rapid whole-brain quantitative magnetization transfer imaging using 3D selective inversion recovery sequences
Institution:1. Department of Psychiatry, Washington University Medical School, St. Louis, United States;2. Department of Radiology, Washington University Medical School, St. Louis, United States;3. Department of Psychology, Washington University in St. Louis, United States;4. Department of Anatomy and Neurobiology, Washington University in St. Louis, United States;1. Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, USA;2. Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232, USA;3. Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232, USA;4. Department of Rheumatology, Vanderbilt University, Nashville, TN 37232, USA;5. Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37232, USA;6. Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN 37232, USA
Abstract:Selective inversion recovery (SIR) is a quantitative magnetization transfer (qMT) method that provides estimates of parameters related to myelin content in white matter, namely the macromolecular pool-size-ratio (PSR) and the spin-lattice relaxation rate of the free pool (R1f), without the need for independent estimates of ∆B0, B1+, and T1. Although the feasibility of performing SIR in the human brain has been demonstrated, the scan times reported previously were too long for whole-brain applications. In this work, we combined optimized, short-TR acquisitions, SENSE/partial-Fourier accelerations, and efficient 3D readouts (turbo spin-echo, SIR-TSE; echo-planar imaging, SIR-EPI; and turbo field echo, SIR-TFE) to obtain whole-brain data in 18, 10, and 7 min for SIR-TSE, SIR-EPI, SIR-TFE, respectively. Based on numerical simulations, all schemes provided accurate parameter estimates in large, homogenous regions; however, the shorter SIR-TFE scans underestimated focal changes in smaller lesions due to blurring. Experimental studies in healthy subjects (n = 8) yielded parameters that were consistent with literature values and repeatable across scans (coefficient of variation: PSR = 2.2–6.4%, R1f = 0.6–1.4%) for all readouts. Overall, SIR-TFE parameters exhibited the lowest variability, while SIR-EPI parameters were adversely affected by susceptibility-related image distortions. In patients with relapsing remitting multiple sclerosis (n = 2), focal changes in SIR parameters were observed in lesions using all three readouts; however, contrast was reduced in smaller lesions for SIR-TFE, which was consistent with the numerical simulations. Together, these findings demonstrate that efficient, accurate, and repeatable whole-brain SIR can be performed using 3D TFE, EPI, or TSE readouts; however, the appropriate readout should be tailored to the application.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号