The minimum in-line coalescence height of bubbles in non-Newtonian fluid
Institution:1. State Key Laboratory of Chemical Engineering, Collaborative Innovation Center of Chemical science and Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, PR China;2. Laboratory of Reactions and Process Engineering, University of Lorraine, CNRS, 1, rue Grandville, BP 20451, 54001 Nancy Cedex, France;1. Laboratoire de Physique, CNRS UMR 5672, École Normale Supérieure de Lyon, Université de Lyon, 46 Allée d’Italie, Lyon 69007, France;2. Laboratoire de Génie des Procédés Catalytiques, CNRS UMR 5285, CPE Lyon, Université de Lyon, 43 Boulevard du 11 Novembre 1918, Villeurbanne 69100, France;1. Laboratoire de Physique, CNRS UMR 5672, École Normale Supérieure de Lyon, Université de Lyon, 46 Allée d’Italie, 69007 Lyon, France;2. Laboratoire de Génie des Procédés Catalytiques, CNRS UMR 5285, CPE Lyon, Université de Lyon, 43 boulevard du 11 novembre 1918, 69100 Villeurbanne, France
Abstract:The minimum in-line coalescence height of bubbles generated from a submerged nozzle was investigated experimentally in shear thinning non-Newtonian fluid at lower Reynolds number (2~60). Carboxymethyl cellulose sodium (CMC) aqueous solution and carbon dioxide were used as the liquid phase and the gas phase, respectively. The process of the formation, movement and in-line coalescence of bubbles was visualized and recorded by a high-speed digital camera. The influences of bubble size, bubble generation frequency and liquid property on the minimum in-line coalescence height of bubbles were investigated by changing nozzle diameter, gas flow rate and the mass concentration of CMC aqueous solutions. For a given liquid, the generating frequency and size of bubbles increased but the minimum coalescence height of in-line bubbles decreased when the nozzle diameter and gas flow rate were increased. When the nozzle diameter and gas flow rate were fixed, the shear-thinning effect of CMC aqueous solution became stronger with increasing CMC mass concentration, which led to the increase in both the terminal rise velocity and average acceleration of the trailing bubble, consequently, the minimum in-line coalescence height of bubbles decreased. An empirical correlation for estimating the minimum in-line bubble coalescence height was proposed, the calculating values accords well with experimental data with a mean relative deviation only 7.6%.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号