Automated Flow Injection Method for Monitoring Total Cyanide Concentration in Petroleum Refinery Effluents Using Ninhydrin as Color Reagent
Authors:Ricardo Erthal Santelli  Alexandre Santos Micelli  Maria de Fátima Batista de Carvalho
Institution:1. Departamento de Geoquímica , Universidade Federal Fluminense , Niterói/RJ, Brazil santelli@geoq.uff.br;3. Departamento de Geoquímica , Universidade Federal Fluminense , Niterói/RJ, Brazil;4. Centro de Pesquisas e Desenvolvimento da PETROBRAS, Avalia??o e Monitoramento Ambiental , Cidade Universitária , Rio de Janeiro/RJ, Brazil
Abstract:Abstract

An automated flow injection system was developed for monitoring cyanide concentration in effluents from petroleum refineries. The method takes advantage of the reaction of cyanide ions with ninhydrin in basic medium in a flow injection system. A linear range of 0.01 to 0.04 µg mL?1 was obtained with a detection limit of 1.5 ng mL?1 by using 500 µL sample injection, with an analytical throughput of 30 samples hr?1, excluding sample pretreatment by distillation if required. Regarding interferences, cyanide can be determined in the presence of 100 mg L?1 of thyocianate and sulfide, both species normally found in industrial effluents. For total cyanide determination, strong acid distillation is recommended due to the presence of cyano‐metallic complexes in the refinery effluents. The method was validated by analyte addition and results compared with the standard methodology proposed by the American Public Health Association (APHA). The more significant advantage of the proposed method is the lack of use of carcinogenic reagent such as pyridine and psychotropic compound such as barbituric acid, both used in the recommended method by APHA. Thus, the proposed method is really a friendly analytical procedure.
Keywords:Cyanide determination  FIA  industrial effluents  ninhydrin  spectrophotometry
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号