首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Analytical quality control: Sampling procedures to detect trace metals in environmental matrices
Authors:Gabriele Capodaglio  Carlo Barbante  Clara Turetta  Giuseppe Scarponi  Paolo Cescon
Institution:(1) Department of Environmental Sciences, University of Venice, Dorsoduro 2137, I-30123 Venice, Italy
Abstract:The problem of contamination during the collection of samples of environmental interest to detect trace metal is discussed. Attention is focused on the leaching of metals from sampling devices used to collect surface and deep seawater. A procedure to test metal release is applied to emphasize the importance of conditioning samplers before use. The procedure for checking the contamination extent and decontamination of firn and ice cores to detect ultratrace elements (particularly Cd and Pb) is presented and applied to some firn cores collected in Antarctica during the 1990–1991 Italian expedition.
Keywords:seawater  snow  differential pulse anodic stripping voltammetry  sampling  quality assurance  cadmium  lead
本文献已被 SpringerLink 等数据库收录!