Temperature dependence of the calibration factor of radon and radium determination in water samples by SSNTD
Authors:I Hunyadi  I Csige  J Hakl  E Barad  cs and Z Dezs
Institution:

a Inst. Nuclear Res. of the Hung. Acad. of Scien., H-4001, Debrecen, POB. 51, Hungary

b Isotope Laboratory, Kossuth University, H-4010, Debrecen, POB. 8, Hungary

Abstract:The sensitivity of a 226Ra determination method of water samples by SSNTD was measured as a function of storage temperature during exposure. The method is based on an etched track type radon monitor, which is closed into a gas permeable foil and is immersed in the water sample. The sample is sealed in a glass vessel and stored for an exposure time of 10–30 days. The sensitivity increased more than a factor of two when the storage temperature was raised from 2 °C to 30 °C. Temperature dependence of the partition coefficient of radon between water and air provides explanation for this dependence. For practical radio-analytical application the temperature dependence of the calibration factor is given by fitting the sensitivity data obtained by measuring 226Ra standard solutions (in the activity concentration range of 0.1–48.5 kBq m−3) at different storage temperatures.
Keywords:222Rn  226Ra  water  CR-39  Radamon  temperature dependence  222Rn gas partition coefficient