首页 | 本学科首页   官方微博 | 高级检索  
     


Heat Transfer in a Tube Fitted with Vertical and Horizontal Wing-Cut Twisted Tapes
Authors:P. Murugesan  K. Mayilsamy  S. Suresh
Affiliation:1. Department of Mechanical Engineering , KSR Institute for Engineering and Technology , Namakkal , India;2. Department of Mechanical Engineering , Institute of Road and Transport Technology , Erode , India;3. Department of Mechanical Engineering , National Institute of Technology , Tiruchirappalli , India
Abstract:This article reports an experimental investigation on the heat transfer, friction factor, and thermal enhancement factor of a tube equipped with vertical wing-cut twisted tapes, horizontal wing-cut twisted tapes, and plain twisted tapes with twist ratios of y = 2.0, 4.4, and 6.0. The obtained results reveal that the heat transfer rate, friction factor, and thermal enhancement factor in the tube equipped with horizontal wing-cut twisted tapes are significantly higher than those in the tube fitted with vertical wing-cut twisted tapes, plain twisted tapes, and a plain tube. An empirical correlation is subsequently derived from the experimental results.
Keywords:heat transfer enhancement  friction factor  plain twisted tape  wing-cut twisted tape  secondary flow