Effects of Chemical Heat Sink Generated by an Oxalic Acid Cooling Stream on Film-Cooling Effectiveness
Authors:K. Cheng  X. Huai
Affiliation:Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing, China
Abstract:Based on the theory of heat transfer enhancement, a novel film-cooling method for turbine blades that involves a chemical heat sink generated by the use of oxalic acid as a cooling stream has been proposed. Experiments were conducted on a flat plate with a row of 30° angled holes, and the conventional method using air as the cooling stream was examined for comparison. Overall, the results of this study demonstrate that the proposed cooling method involving an oxalic acid-induced chemical heat sink is more effective than the conventional method.
Keywords:turbine blades  chemical heat sink  oxalic acid  film-cooling effectiveness