首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simultaneous analysis of trans- and cis-isomers of 2-glucosyloxycinnamic acids and coumarin derivatives in Dendrobium thyrsiflorum by high-performance liquid chromatography (HPLC)-photodiode array detection (DAD)-electrospray ionization (ESI)-tandem mass spectrometry (MS)
Authors:Zhang Guangnong  Zhang Fang  Yang Li  Zhu Enyuan  Wang Zhengtao  Xu Luoshan  Hu Zhibi
Institution:a Key Laboratory of Standardization of Chinese Medicines of Ministry of Education, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, 1200 Cai Lun Road, Zhangjiang Hi-Tech Park, Shanghai 201203, China
b Department of Pharmacognosy, China Pharmaceutical University, Nanjing 210038, China
Abstract:A novel method has been developed for simultaneous analysis for three pairs of trans- and cis-isomers of 2-glucosyloxycinnamic acids, along with their biogenic metabolites (three coumarin derivatives including scopoletin, scoparone and ayapin) in a Chinese medicinal herb Dendrobium thyrsiflorum by using high-performance liquid chromatography (HPLC)-photodiode array detection (DAD)-electrospray ionization (ESI)-tandem mass spectrometry (MS). The method was carried out by using a Polaris C18 column with a gradient solvent system of 0.5% acetic acid aqueous solution-acetonitrile. Seven target analytes including isodensifloside, isothyrsifloside, densifloside, thyrsifloside, scoparone, ayapin and scopoletin were exclusively identified by comparing their retention behaviors, UV and MS spectra with the authentic standards, and their contents in D. thyrsiflorum were simultaneous determined by employing UV detection at 342 nm. In addition, another pair of isomers of 2-glucosyloxycinnamic acids was putatively elucidated mainly based on the MS fragmentation. The method was validated and found to be satisfactorily linear, selective and robust. Recoveries ranged from 95.56 to 97.94% for all compounds at three different spiking levels. The limits of detection (LOD) and quantitation (LOQ) ranged, respectively, from 0.02 to 0.13 μg mL−1 and 0.07 to 0.39 μg mL−1 depending on various compounds. The established quality evaluation method was successfully used for evaluating the quality of D. thyrsiflorum samples of different organs and collections.
Keywords:Dendrobium thyrsiflorum  2-Glucosyloxycinnamic acid  Coumarin  High-performance liquid chromatography (HPLC)-photodiode array detection (DAD)-electrospray ionization (ESI)-tandem mass spectrometry (MS)  Quality evaluation
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号