Simultaneous Determination of Organic Acids in Wine Samples by Capillary Electrophoresis and UV Detection: Optimization with Five Different Background Electrolytes
Authors:A Castieira  R M Pea  C Herrero  S García‐Martín
Abstract:A simple technique is described for the routine capillary electrophoretic determination of organic acids in wine samples. Several aromatic and non‐aromatic compounds, including phthalic acid, benzoic acid, sorbic acid, boric acid, and phosphate, were evaluated as background electrolytes in order to obtain the highest resolution and detection sensivity. Factors that affect capillary electrophoretic separation such as the concentration and pH of the background electrolyte (BGE), the concentration of the electroosmotic flow modifier (EOF), and methanol addition to the electrolyte were investigated systematically. Tartaric, malic, succinic, acetic, and lactic acids were determined simultaneously in approximately six minutes using an electrolyte containing 3 mM phosphate and 0.5 mM myristyltrimethylammonium bromide (MTAB) as electroosmotic flow modifier at pH 6.5. This method is quantitative, with recoveries in the 90–102% range and linear up to 50 mg L–1. The precision is better than 1% and the procedure shows the appropriate sensibility, with detection limits between 0.015 and 0.054 mg L–1. The proposed method was successfully employed for the determination of organic acids in wine samples by direct sample injection after appropriate dilution and filtration.
Keywords:Capillary electrophoresis  UV detection  organic acids  background electrolyte optimization  wine