Monitoring of safety features,fissile material accumulation and concentration in nuclear reprocessing by active and passive neutron counting techniques |
| |
Authors: | E. Gantner U. Kuhnes H. J. Ache |
| |
Affiliation: | (1) Institut für Radiochemie, Kernforschungszentrum Karlsruhe, P.O. Box 3640, 7500 Karlsruhe, (Germany) |
| |
Abstract: | The application, the advantage and limits of neutron monitoring techniques, such as Hf-monitors, fissile material accumulation and concentration monitors are being discussed. The active neutron counting technique applied to emptied pulsed extraction columns containing Hf-sieve plates allows conclusive answers as to the position of the plates in the columns. Pu-accumulations on Hf-sieve plates in pulsed extraction columns can be estimated within a factor of two, whereby the detection limit is about equal to or less than 1 g Pu/plate. Fissile material concentration changes of 1.1 g/l can be detected in the case of235U in solution and of 0.4 Pu/l if a239Pu/240Pu ratio of 4 to 1 is assumed. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|