首页 | 本学科首页   官方微博 | 高级检索  
     


Monitoring of safety features,fissile material accumulation and concentration in nuclear reprocessing by active and passive neutron counting techniques
Authors:E. Gantner  U. Kuhnes  H. J. Ache
Affiliation:(1) Institut für Radiochemie, Kernforschungszentrum Karlsruhe, P.O. Box 3640, 7500 Karlsruhe, (Germany)
Abstract:The application, the advantage and limits of neutron monitoring techniques, such as Hf-monitors, fissile material accumulation and concentration monitors are being discussed. The active neutron counting technique applied to emptied pulsed extraction columns containing Hf-sieve plates allows conclusive answers as to the position of the plates in the columns. Pu-accumulations on Hf-sieve plates in pulsed extraction columns can be estimated within a factor of two, whereby the detection limit is about equal to or less than 1 g Pu/plate. Fissile material concentration changes of 1.1 g/l can be detected in the case of235U in solution and of 0.4 Pu/l if a239Pu/240Pu ratio of 4 to 1 is assumed.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号