首页 | 本学科首页   官方微博 | 高级检索  
     


Schistosoma japonicum antibody assay by immunosensing with fluorescence detection using 3,3',5,5'-tetramethylbenzidine as substrate
Authors:Gong Fu-Chun  Zhou Zhi-Jun  Shen Guo-Li  Yu Ru-Qin
Affiliation:State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, PR China.
Abstract:An immunosensing system for Schistosoma Japonicum antibody (SjAb) assay has been developed which is useful for the diagnosis of schistosomaisis. To circumvent the difficulty of regeneration of the immunosensing device, the sol-gel technique is used which results in a considerable retention of the activity of the encapsulated antigen (SjAb) and easily diffusing into the pores of the polymeric silica matrix. The surface of the immunosensing device prepared can easily be renewed by simply polishing. The regenerated surface serves as a platform for the competitive immuno-reaction of HRP-SjAb and SjAb with SjAg bound at the surface. By using 3, 3', 5, 5'-tetramethylbenzidine (TMB) as the substrate, the amount of HRP-SjAb bound is quantitated fluorimetrically, which is in turn related with the SjAb content. An amplification effect is obtained by using the enzymatic reaction, and an improved detection limit of 4.5 ng ml(-1) is thus realized. The optimum analytical conditions such as pH, amount of the labeled antibody and flow rates of substrate carrier solution were established. The immunosensing procedure shows a pseudo linear response range from 4.5 to 55 ng ml(-1). The proposed procedure has been employed to determine SjAb in serum samples.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号