Extraction-spectrometric determination of lead in high-purity aluminium salts |
| |
Authors: | Kokšal Jiřı́ Synek Václav Janoš Pavel |
| |
Institution: | Research Institute of Inorganic Chemistry, Revolucni 84, 400 01 Usti nad Labem, Czech Republic. |
| |
Abstract: | Trace amounts of lead were determined in high purity aluminium salts (especially in ammonium aluminium sulfate) using inductively coupled plasma-optical emission spectrometry (ICP-OES) after extractive pre-concentration and matrix separation. Metals were extracted from the aluminium matrix in the form of chelates with ammonium pyrolidine dithoocarbamate into methyl isobutyketone. The organic extract was digested with nitric acid and hydrogen peroxide. The limit of detection for the determination of lead in crystalline ammonium aluminium sulfate was ca. 0.044 mug g(-1). The relative expanded uncertainty of the lead determination was ca. 23% at the level of 0.2 mug g(-1) and ca. 16% at the level of 1.0 mug g(-1). The main uncertainty contribution was associated with repeatability of the whole analytical procedure. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |