On the effect of marangoni flow on evaporation rates of heated water drops |
| |
Authors: | Girard F Antoni M Sefiane K |
| |
Affiliation: | School of Engineering and Electronics, University of Edinburgh, Kings Buildings, Edinburgh, EH9 3JL, United Kingdom. |
| |
Abstract: | In this letter we show that the Marangoni flow contribution to the evaporation rate of small heated water droplets resting on hot substrates is negligible. We compare data of evaporating droplet experiments with numerical results and assess the effect of Marangoni flow and its contribution to the evaporation process. We demonstrate that heat conduction inside these water droplets is sufficient to give an accurate estimate of evaporation rates. Although convection in evaporating water droplets remains an open problem, our aim in this study is to demonstrate that these effects can be neglected in the investigation of evaporation rate evaluation. It is worth noting that the presented results apply to volatile heated drops which might differ from spontaneously evaporating cases. |
| |