首页 | 本学科首页   官方微博 | 高级检索  
     


Monitoring of antifouling agents in water samples by on-line solid-phase extraction-liquid chromatography-atmospheric pressure chemical ionization mass spectrometry
Authors:Gimeno R A  Aguilar C  Marcé R M  Borrull F
Affiliation:Departament de Química Analítica i Química Orgànica, Universitat Rovira i Virgili, Tarragona, Spain.
Abstract:An automatic method for determining diuron, irgarol 1051, folpet and dichlofluanid in seawater samples have been developed. This method is based on the on-line coupling of solid-phase extraction (SPE) with a highly crosslinked polymeric sorbent, LiChrolut EN, to liquid chromatography followed by atmospheric pressure chemical ionization (APCI) and mass spectrometry. The operational parameters affecting the APCI interface have been studied in both positive and negative ionization modes. The use of LiChrolut EN in the SPE produced recoveries of over 85% for all the compounds when 100 ml of seawater sample was preconcentrated. Calibration was carried out in both ionization modes and in full-scan and selected-ion monitoring (SIM). The method allowed all the analytes to be detected at 5 ng l(-1) in SIM acquisition mode except folpet, which, because of its low response, could only be detected at 250 ng l(-1). The method was used to analyse water samples taken from five different marina and fishing ports along the coast of Tarragona, Catalonia (Spain), over a 5-month period. Diuron and irgarol 1051 were detected and quantified in most samples at concentration levels ranging from 27 to 420 ng l(-1) for diuron and from 15 to 511 ng l(-1) for irgarol 1051.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号