首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A simple estimate for the effect of cross sensitivity on evaluated strain-gage measurement
Authors:M L Meyer
Institution:1. Department of Mechanical Engineering, The City University, London
Abstract:The cross-sensitivity factor of a short-wire strain gage can sometimes be estimated by comparison of its gage factor with that of a long gage of similar construction and material. A plot of the error introduced by the usual neglect of cross sensitivity against the known or estimatedtrue ratio of transverse to longitudinal stress or strain yields a quick estimate for any given cross-sensitivity factorn of the gage, any Poisson's ratio ν of the test piece and any stress or strain ratio. It shows whether in any particular test the influence of cross sensitivity warrants further special attention. If the longitudinal strain exceeds the transverse strain, the error is seen to be always less than 1.3n, but if the transverse strain is larger, the error may be so high as to vitiate the result. In computations from rosette measurements, the diagram shows that the larger principal stress can be determined with an error below 1.3n, as can Tresca's and von Mises's criteria of yield, while the error in the smaller principal stress tends to be large for principal strain ratios above +10 or below ?1.5.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏