摘    要:简单介绍了重离子治癌的原理, 叙述了一种用于重离子治癌的大面积平行板雪崩计数器, 它主要由入射窗、 x位置栅极、 中心阳极、 y位置栅极和出射窗组成. 使用C3F8气体, 气压700 Pa, 阳极电压为700 V, 两阴极接地, 电子学成形时间常数为2 μs, 测试得到的位置分辨修正后为0.54 mm(FWHM). 通过与国内外同类装置比较, 认为这一分辨已经满足了重离子治癌装置的要求. he principle of the heavy ion therapy is introduced in this article. In order to precisely determine the irradiation profiles and positions of scanned heavy ion beams, we developed a large area parallel plate avalanche counter(PPAC). The detector consists of one anode, two cathodes and two windows with 250 mm×250 mm active area . It was measured at an anode voltage of 700 V and with flowing C3F8 gas at the pressure of 700 Pa. A position resolution of 0.54 mm by correction was obtained with an α source. As compared with the similar devices, we consider the position resolution of the PPAC can satisfy the requirement of the facility of heavy ion therapy.

关 键 词:重离子治癌   大面积平行板雪崩计数器   位置分辨
文章编号:1007-4627(2004)01-0017-04
收稿时间:1900-01-01
修稿时间:2003-07-08

A Large Area PPAC for Using in Tumor Therapy with Heavy Ions
HU Zheng-guo,GUO Zhong-yan,ZHAN Wen-long,XIAO Guo-qing,XU Hu-shan,WANG Meng,MAO Rui-shi,Li Jia-xing,SUN Zhi-yu,CHEN Zhi-qiang,CHEN Li-xin,BAI Jie,LI Chen,ZHANG Jin-xia,LI Cun-fan. A Large Area PPAC for Using in Tumor Therapy with Heavy Ions[J]. Nuclear Physics Review, 2004, 21(1): 17-20. DOI: 10.11804/NuclPhysRev.21.01.017
Authors:HU Zheng-guo  GUO Zhong-yan  ZHAN Wen-long  XIAO Guo-qing  XU Hu-shan  WANG Meng  MAO Rui-shi  Li Jia-xing  SUN Zhi-yu  CHEN Zhi-qiang  CHEN Li-xin  BAI Jie  LI Chen  ZHANG Jin-xia  LI Cun-fan
Affiliation:Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
Abstract:he principle of the heavy ion therapy is introduced in this article. In order to precisely determine the irradiation profiles and positions of scanned heavy ion beams, we developed a large area parallel plate avalanche counter(PPAC). The detector consists of one anode, two cathodes and two windows with 250 mm×250 mm active area . It was measured at an anode voltage of 700 V and with flowing C3F8 gas at the pressure of 700 Pa. A position resolution of 0.54 mm by correction was obtained with an α source. As compared with the similar devices, we consider the position resolution of the PPAC can satisfy the requirement of the facility of heavy ion therapy.
Keywords:heavy-ion therapy  large area parallel plate avalanche counter  position resolution
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号