Transmission positron microscopes
Authors:Masao Doyama  Yoshiaki Kogure  Toshikazu Kurihara  Ryuichiro Oshima
Institution:a Teikyo University of Science and Technology, Uenohara, Yamanashi 409-0193, Japan
b Institute of Materials Structure Science (IMSS), High Energy Accelerator, Research Organization (KEK), Ohno 1-1, Tsukuba, Ibaraki 305-0801, Japan
c Reactor Research Institute, Kyoto University, Noda, Kumatori, Osaka 590-0451, Japan
d Research Institute for Advanced Science and Technology, Osaka Prefecture University, Japan
e Electron Optics Laboratory (JEOL) Ltd., Musashino 3-1-2, Akishima 196-0021, Japan
Abstract:Immediate and near-future plans for transmission positron microscopes being built at KEK, Tsukuba, Japan, are described. The characteristic feature of this project is remolding a commercial electron microscope to a positron microscope. A point source of electrons kept at a negative high voltage is changed to a point source of positrons kept at a high positive voltage. Positional resolution of transmission microscopes should be theoretically the same as electron microscopes. Positron microscopes utilizing trapping of positrons have always positional ambiguity due to the diffusion of positrons.
Keywords:Positron microscopes  Positron-electron microscopes  Transmission  Positron microscopes