首页 | 本学科首页   官方微博 | 高级检索  
     


Characterization of post-copper CMP surfaces with scanning probe microscopy: Part 1: Surface leakage measurement with conductive atomic force microscopy
Authors:A. Dominget  S. Szunerits
Affiliation:a Freescale Semiconductor, Crolles2 Alliance, 870 Rue Jean Monnet, 38926 Crolles, France
b Laboratoire d’Electrochimie et de Physicochimie des Matériaux et des Interfaces (LEPMI), CNRS-INPG-UJF, 1130 Rue de la Piscine, BP 75, 38402 St. Martin d’Hères, France
Abstract:We demonstrate in this paper for the first time the use of conductive atomic force microscopy (AFM) to measure surface leakage between copper structures with varying line width and spacing in the micro and sub micrometer ranges. Conducting atomic force microscopy allows subsequent measurement of the topography as well as the electrical properties of surfaces. The feasibility and interest of these measurements will be shown by studying the impact of chemical mechanical polishing (CMP) of an electrical interface bearing different micrometric copper structures. As expected the polishing time has a crucial impact on the current determined between closely spaced copper structures. This paper will also deal with issues observed during the measurement.
Keywords:Atomic force microscopy (AFM)   Surface leakage   Chemical mechanical polishing (CMP)   Copper interconnects
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏