首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effects of measurement errors on refractive outcomes for pseudophakic eye based on eye model
Authors:Yongji Liu  Guoguang Mu
Institution:Key Laboratory of Opto-electronic Information Science and Technology of MOE, Institute of Modern Optics, Nankai University, Tianjin, China
Abstract:With the Gullstrand-Le Grand eye model, the effects of various measurement errors on refractive outcomes for pseudophakic eye are studied. An equation to calculate the postoperative refractive error for pseudophakic eyes is derived. The accuracy to get a refractive error less than ca. 25 D is ±0.1 mm for the axial length, ±0.03 mm for the radius of the corneal anterior surface, ±0.12 D for the corneal power and ±0.16 mm for the postoperative anterior chamber depth (ACD). An error of 1 D in intraocular lens (IOL) power leads to a postoperative refractive error of −0.69 D. K-reading leads to a postoperative hyperopia from 0.18 to 0.74 D for eye with different refractive errors previously corrected. The constant velocity in ultrasound biometry assumption overestimates the axial length from 0.17 to 0.31 mm with actual axial length ranging from 21.31 to 32.31 mm. Errors in axial length, corneal power or radius of the corneal anterior surface and postoperative ACD play critical roles in determining the refractive outcomes. The constant-velocity assumption tends to overestimate the axial length. The change of the ratio of corneal anterior to the posterior surface is of minor importance for the overestimation of K-reading.
Keywords:Eye model  Pseudophakic eye  Postoperative refractive error  IOL  Measurement error
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号