Applicability study on existing dosimetry systems to high-power Bremsstrahlung irradiation
Authors:Kishor Mehta  Takuji Kojima  Hiromi Sunaga
Institution:

a Bruenner Strasse 133-3-29, Vienna A-1210, Austria

b Japan Atomic Energy Research Institute, 1233 Watanuki, Takasaki, Gunma 370-1292, Japan

Abstract:Applicability of the existing dosimetry systems to high-power Bremsstrahlung irradiation was investigated through a dose intercomparison study, where several dosimeters were irradiated in the dose range 4–12 kGy in identical polyethylene phantoms in a Bremsstrahlung beam obtained from a 5-MeV electron accelerator. Included in the study were alanine dosimeters molded by three different binders, three types of liquid dosimeters—ceric-cerous, dichromate and ethanol-chlorobenzen (ECB), and glutamine powder. The dosimeter responses for Bremsstrahlung radiation were analyzed at the issuing laboratories, and the dose values determined using calibration based on cobalt-60 gamma-ray irradiation. Dose values for all the three dose levels for all dosimetry systems were in good agreement—better than 3%. The results of the study demonstrate that these existing dosimetry systems have a potential for application to high-power Bremsstrahlung irradiation.
Keywords:Dose intercomparison  Bremsstrahlung  X-rays  Radiation processing  High-dose dosimetry