首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effects of thermal treatment on hydrophilicity and corrosion resistance of Ti surface
Authors:Suwimon Boonrungsiman  Panida Prompinit  Pongtanawat Khemthong  Tuksadon Wutikhun  Alongkot Treethong  Panita Kasamechonchung  Narong Chanlek  Rawiwan Maniratanachote  Mati Horprathum  Apirak Pankiew  Suppanit Pornthreeraphat  Narathon Khemasiri  Annop Klamchuen
Institution:1. National Nanotechnology Center (NANOTEC), NSTDA, Klong Luang, Thailand;2. Synchrotron Light Research Institute, Nakhon Ratchasima, Thailand;3. National Electronics and Computer Technology Center (NECTEC), Klong Luang, Thailand;4. College of Nanotechnology, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand
Abstract:Surface treatment of titanium (Ti) surface has been extensively studied to improve its properties for biomedical applications, including hydrophilicity, corrosion resistance, and tissue integration. In this present work, we present the effects of thermal oxidation as surface modification method on metallic titanium (Ti). The Ti foils were oxidized at 300°C, 400°C, 500°C, and 600°C under air atmosphere for 3 hours, which formed oxide layer on Ti surface. The physicochemical properties including surface chemistry, roughness, and thickness of the oxide layer were evaluated in order to investigate how these factors affected surface hydrophilicity, microhardness, and corrosion resistance properties of the Ti surface. The results revealed that surfaces of all oxidized samples were modified by formation of titanium dioxide layer, of which morphology, phase, and thickness were changed according to the oxidized temperatures. Increasing oxidation temperature led to the formation of thicker oxide layer and phase transformation of anatase to rutile. The presence of the oxide layer helped the improvement of corrosion resistance and microhardness. The most improvement in surface roughness was found in the specimens treated at 400°C, which significantly improved surface hydrophilicity. But both surface roughness and hydrophilicity reduced when oxidized at 500°C and 600°C, suggesting that hydrophilicity was dominated by the surface roughness. In addition, this surface treatment did not reduce the biocompatibility of the metallic Ti substrates against murine osteoblasts (MC3T3).
Keywords:corrosion resistance  hardness  hydrophilicity  thermal oxidation  XPS and Ti surface treatment
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号