In vivo physiological saline‐infused hepatic vessel imaging using a two‐crystal‐interferometer‐based phase‐contrast X‐ray technique
Authors:Tohoru Takeda  Akio Yoneyama  Jin Wu    Atsushi Momose  Kazuyuki Hyodo
Abstract:Using a two‐crystal‐interferometer‐based phase‐contrast X‐ray imaging system, the portal vein, capillary vessel area and hepatic vein of live rats were revealed sequentially by injecting physiological saline via the portal vein. Vessels greater than 0.06 mm in diameter were clearly shown with low levels of X‐rays (552 µGy). This suggests that in vivo vessel imaging of small animals can be performed as conventional angiography without the side effects of the presently used iodine contrast agents.
Keywords:in vivo hepatic vessel imaging  two‐crystal interferometer  phase‐contrast X‐ray technique  physiological saline