Determination of ferrous ion in microsamples of hexagonal ferrites
Authors:F Licci
Institution:(1) Laboratorio MASPEC del C. N. R., Parma, Italy
Abstract:Summary A sensitive and accurate method is described for determining microgram amounts of ferrous iron associated with a large excess of ferric iron and various bivalent cations, in hexagonal ferrites. Ferrous iron is complexed with bathophenanthroline, extracted into a chloroform-ethanol mixture and spectrophotometrically measured at 540 nm against a 1ratio3 v/v chloroform-ethanol mixture. Ferric iron is masked with ammonium dihydrogen phosphate. The analytical conditions are stated for determination of iron(II) in both solvents used for ferrites, viz., hydrochloric and phosphoric acids. Cobalt, copper, and nickel do not interfere if the procedures suggested are used. Ferrous iron down to 0.02% can be determined in samples weighing only a few milligrams.
Zusammenfassung Eine empfindliche und genaue Methode zur Bestimmung von Mikrogrammengen Eisen(II) in Gegenwart eines großen Überschusses von Eisen(III) und verschiedener zweiwertiger Kationen in hexagonalen Ferriten wurde beschrieben. Eisen(II) wird mit Bathophenanthrolin komplex gebunden, mit einer Chloroform-Äthanol-Mischung extrahiert und bei 540 nm gegen eine Chloroform-Äthanol-Mischung (1ratio3 v/v) spektrophotometrisch gemessen. Eisen(III) wird mit NH4 · H2PO4 maskiert. Die Arbeitsbedingungen für die Bestimmung von Eisen(II) in beiden für Ferrite verwendeten Lösungsmitteln — Salzsäure und Phosphorsäure — wurden festgelegt. Co, Cu und Ni stören die empfohlenen Verfahren nicht. Bis zu 0,02% Eisen(II) können in Einwaagen von wenigen Milligramm bestimmt werden.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号