Phase split of liquid–liquid two-phase flow at a horizontal T-junction
Authors:L Yang  BJ Azzopardi
Institution:Multiphase Flow Research Group, Nottingham Fuel and Energy Centre, School of Chemical, Environmental and Mining Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
Abstract:This paper provides data on the split of liquid/liquid two-phase flow at a horizontal T-junction. Phase maldistribution was measured for kerosene–water flow at the T-junction with equal pipe diameters of 67.4 mm. Data were taken with both stratified flow with a mixture at interface and dispersed flows approaching the junction. The degree of phase maldistribution was not very great but preferential emergence of either phase from the side-arm was observed depending on the flow rates of the two-phases. There are similarities with the limited split data from liquid/solid flows and the degree of separation is seen to depend on the dispersed/continuous phase density ratio. The data were compared to predictions from the correlation by Seeger et al. The Seeger equation gives but reasonable agreement.
Keywords:Liquid/liquid  T-junction  Horizontal