Determination of methotrexate in human serum by high-performance liquid chromatography combined with pseudo template molecularly imprinted polymer |
| |
Authors: | Xiangjun Liu Jizhong LiuYanyan Huang Rui ZhaoGuoquan Liu Yi Chen |
| |
Affiliation: | Beijing National Laboratory for Molecular Sciences, Lab of Analytical Chemistry for Life Science, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China |
| |
Abstract: | A pseudo template molecularly imprinted polymer (MIP) was prepared for methotrexate (MTX) and a RP-HPLC method combined with the MIP was developed for the determination of MTX in human serum. Because of the poor solubility of MTX in common MIP preparation solvents, trimethoprim (TMP), a molecule having the similar imprinting sites as MTX, is selected as the pseudo template. The MIP was prepared using methacrylic acid (MAA) and ethylene glycol dimethacrylate as functional monomer and cross-linker, respectively. 1H NMR study showed highly strong interaction between TMP and MAA with hydrogen bonds. Chromatographic behaviors indicated that the TMP-MIP possessed excellent affinity and selectivity for MTX. And the imprinting factor for MTX was high up to 9.5 when 7:3 of acetonitrile:methanol (v/v) was used as mobile phase. Moreover, TMP-MIP was used as the solid-phase extraction (SPE) material to enrich the target compound MTX in human serum samples for HPLC analysis. The SPE process was carefully optimized and good recoveries of MTX were obtained as 81.6–86.2% with RSD of 0.22–1.84% when the spiked concentration of MTX was 2.0–10.0 μg mL−1 in human serum samples. The results indicated that the pseudo template MIP can be applied to preconcentration, purification and analysis of MTX in clinic samples. |
| |
Keywords: | Molecularly imprinted polymer Pseudo template Methotrexate Solid-phase extraction Human serum analysis |
本文献已被 ScienceDirect 等数据库收录! |
|