首页 | 本学科首页   官方微博 | 高级检索  
     


Free-field release from masking
Authors:K Saberi  L Dostal  T Sadralodabai  V Bull  D R Perrott
Affiliation:Psychoacoustics Laboratory, California State University, Los Angeles 90032.
Abstract:Free-field release from masking was studied as a function of the spatial separation of a signal and masker in a two-interval, forced-choice (2IFC) adaptive paradigm. The signal was a 250-ms train of clicks (100/s) generated by filtering 50-microseconds pulses with a TDH-49 speaker (0.9 to 9.0 kHz). The masker was continuous broadband (0.7 to 11 kHz) white noise presented at a level of 44 dBA measured at the position of the subject's head. In experiment I, masked and absolute thresholds were measured for 36 signal source locations (10 degree increments) along the horizontal plane as a function of seven masking source locations (30 degree increments). In experiment II, both absolute and masked thresholds were measured for seven signal locations along three vertical planes located at azimuthal rotations of 0 degrees (median vertical plane), 45 degrees, and 90 degrees. In experiment III, monaural absolute and masked thresholds were measured for various signal-masker configurations. Masking-level differences (MLDs) were computed relative to the condition where the signal and mask were in front of the subjects after using absolute thresholds to account for differences in the signal's sound-pressure level (SPL) due to direction. Maximum MLDs were 15 dB along the horizontal plane, 8 dB along the vertical, and 9 dB under monaural conditions.