首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Comparison of phototoxicity mechanism between pulsed and continuous wave irradiation in photodynamic therapy
Authors:Miyamoto Y  Umebayashi Y  Nishisaka T
Institution:School of Materials Science, Japan Advanced Institute of Science and Technology, Ishikawa, Japan. yuuichi@jaist.ac.jp
Abstract:A study has been conducted in which HeLa cells are incubated with hematoporphyrin derivative (HpD) for 1 h (1 microgram/ml of HpD in PBS) to compare the use of continuous wave (CW) and pulsed laser (10 Hz repetition rate and 7-9 ns pulse width) light for photodynamic therapy. Cytotoxic effects on the cells are evaluated by the 3-(4,5-dimethyl-2-thiazolyl)-2-5-diphenyl-2H-tetrazolium bromide (MTT) assay and the fluorescein diacetate (FDA)/propidium iodide (PI) stain method using a flow cytometer. The type of cell death is estimated by analysis of the DNA content and observation of the nuclear morphology. The cytotoxicity ratio of cells irradiated by pulsed laser light is estimated to be lower than that for CW laser light. The viability of cells that received pulsed laser light gradually decreases, whereas no significant changes are found in the cells irradiated with CW laser light with the elapse of post-irradiation time. The type of cell death differs between the pulsed and CW laser light irradiations. These findings suggest that the cytotoxic efficacy of the excitation light source is displayed by the difference in the type of cell death, namely apoptosis or necrosis.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号