Abstract:Cross-correlation flowmeters using clamp-on ultrasonic transducers are particularly attractive for use in hostile or abrasive fluids. However, a phase difference is frequently found to exist between the envelopes of the received ultrasonic signals, which causes the correlation peak to become degraded, distorted, or even inverted. In this paper, an explanation for the phase errors is offered, and a new demodulation method, which eliminates these errors, is described.