首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A simple method to adjust cooling rates for supercooling point determination
Authors:Carrillo M A  Kaliyan N  Cannon C A  Morey R V  Wilcke W F
Institution:Department of Entomology, University of Minnesota, Saint Paul, MN 55108, USA.
Abstract:A simple method to obtain predetermined constant cooling rates for insect supercooling point (SCP) determination is described. A transient heat transfer equation was used to design polystyrene cubes of different sizes to yield constant rates of cooling at their centers when held at a constant surrounding temperature. Cubes of 0.29 x 0.29 x 0.29 m and 0.19 x 0.19 x 0.19 m were found to produce cooling rates of about -0.5 and -1 degree C per min, respectively, from 0 to -40 degree C. The observed temperature variations at the geometrical center of the cubes were similar to those predicted by the equation. Temperature plots showed a nearly constant rate of cooling. Supercooling points of Tribolium castaneum (Herbst) at different stages of development were recorded using polystyrene cubes. These SCPs compared favorably with published values. This method of obtaining cooling rates is economical, flexible, and allows for multiple simultaneous SCP measurements.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏