复合绝热低温容器真空丧失后抗热冲击分析
引用本文:朱鸣,徐彬,于忠杰,汪荣顺. 复合绝热低温容器真空丧失后抗热冲击分析[J]. 低温与超导, 2012, 40(1): 19-21,35
作者姓名:朱鸣  徐彬  于忠杰  汪荣顺
作者单位:上海交通大学制冷与低温工程研究所,上海,200240
摘    要:真空丧失对低温容器的安全性是一大威胁,可能会造成严重后果。文中通过实验,利用氮气为破空介质,对比了高真空多层绝热结构与真空复合多层绝热结构低温容器在真空丧失情况下的排放率和漏热。结果表明,复合绝热结构在真空破坏时能较好的保护低温容器,大大降低了低温储罐真空丧失后的热冲击。

关 键 词:真空复合多层绝热  真空丧失  排放率  热流密度

The analysis of anti-thermal shock in the compounded insulation cryogenic tank after loss of vacuum
Zhu Ming , Xu Bing , Yu Zhongjie , Wang Rongshun. The analysis of anti-thermal shock in the compounded insulation cryogenic tank after loss of vacuum[J]. Cryogenics and Superconductivity, 2012, 40(1): 19-21,35
Authors:Zhu Ming    Xu Bing    Yu Zhongjie    Wang Rongshun
Affiliation:(Institute of Refrigeration and Cryogenics,Shanghai Jiaotong University,Shanghai 200240,China)
Abstract:Sudden loss of the vacuum of a cryogenic vessel could bring about serious consequences.This paper presented an experimental investigation on the response of the cryogenic tank with high vacuum multilayer insulation and vacuum compound multilayer insulation after nitrogen was introduced into the insulation jacket.The experimental results showed that compound insulation structure could protect the cryogenic tank and weakened the thermal shock..
Keywords:Vacuum compounded multi-layers insulation  Vacuum loss  Venting rate  Heat flux