Rigorous investigation of heat pump assisted distillation
Institution:1. Environment and Energy Management Development Department, Toyo Engineering Corporation, 2-8-1 Akanehama, Narashino-shi, Chiba 275 0024, Japan;2. Process and Technology Sales, Koch-Glitsch Italia Srl-Unipersonale, Via Torri Bianche, 3/A, 20871 Vimercate, MB, Italy;3. Department of Chemical Engineering, Kyoto University, Katsura Campus, Nishikyo-ku, Kyoto 615 8510, Japan;1. School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, PR China;2. National Engineering Research Center of Distillation Technology, Tianjin, 300072, PR China;3. Collaborative Innovation Center of Chemical Science and Engineering, Tianjin, 300072, PR China;1. University “Politehnica” of Bucharest, Polizu 1-7, 011061 Bucharest, Romania;2. AkzoNobel Research, Development & Innovation, Process Technology SRG, Zutphenseweg 10, 7418 AJ Deventer, The Netherlands;3. Sustainable Process Technology Group, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands;1. School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, PR China;2. School of Chemical Engineering, Yeungnam University, Gyeongsan, 712-749, South Korea
Abstract:In this work a propylene-propane splitter assisted by a heat pump of the vapour recompression type is investigated by rigorous methods. Two schemes, a single compressor scheme and a double compressor scheme in parallel arrangement, are scrutinised and compared to the conventional stand alone column. The investigation includes parametric study, operability assessment and an estimation of the role of heat pump in minimising flue gas emissions. The parametric study of the influences of the column top pressure and the pressure lift of the heat pump on the economics shows, for both schemes at the optimal conditions, practically the same annual total cost, which is about 37% cheaper than the conventional stand alone column.The operability of the system is investigated by degrees of freedom analysis and steady state controllability parameters. The operability considerations show that in the case of the double compressor scheme, the column pressure can be independent of the threshold temperature of the condenser. Thus the column pressure can be determined to satisfy the optimum separation parameters. Due to this operability reason, the double compressor scheme is preferred to the single compressor scheme. The heat pump share in reducing flue gas emissions is estimated. It is found that about 60% of the flue gas emissions can be minimised when using a heat pump.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号