首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Mobile gamma-irradiation robot
Authors:J Teply  C Franek  J Vocilka  R Stetka  J Vins  J Krotil  A Garba
Abstract:The source container with 98 TBq of 137Cs and shielding made from depleted uranium has the total weight of 264 kg, height of 0.370 and diameter 0.272 m. The container is joined to accessories allowing movment of the radiation beam. The dose rate at a distance of 0.4 m in the beam axis is 50 Gy/h. Various technical means are available for manipulation and transport. The irradiation process proceeds according to a precalculated program.The safety measures have been taken to secure the possible application in historical buildings and similar objects. The licence from health physics authorities has been obtained. The first irradiation process performed is described.
Keywords:Irradiation facility  137Cs  transportable  automation  technical and radiation parameters  radiation preservation  antiques  licencebility
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号