首页 | 本学科首页   官方微博 | 高级检索  
     


Intermittent simulated moving bed chromatography: 2. Separation of Tröger’s base enantiomers
Authors:Shigeharu Katsuo  Marco Mazzotti
Affiliation:Institute of Process Engineering, ETH Zurich, Sonneggstrasse 3, CH-8092 Zurich, Switzerland
Abstract:The intermittent simulated moving bed (I-SMB) process is a modification of the conventional SMB process that has been recently analyzed theoretically [1]. Here, we present a comparative analysis of the two processes, each operated in a six column 1-2-2-1 configuration (one column in sections 1 and 4 and two columns in sections 2 and 3) and in a four-column 1-1-1-1 configuration. Experiments are carried out on a properly modified laboratory unit to separate racemic mixtures of the enantiomers of Tröger’s base in ethanol on ChiralPak AD at a total feed concentration of 1 g/L. Simulations are carried out for the same system using the equilibrium dispersive model and a bi-Langmuir isotherm, whose parameters have been preliminarily estimated from pulse and breakthrough experiments. Experiments and simulations are fully consistent and demonstrate that the four-column I-SMB process (but not the four-column SMB process) can separate the two enantiomers at very high purity and achieve a productivity twice as large as that of the six-column I-SMB and conventional SMB processes with the same solvent consumption.
Keywords:Simulated moving bed chromatography   I-SMB   Separation of enantiomers   Trö  ger&rsquo  s base
本文献已被 ScienceDirect 等数据库收录!