Structure elucidation of highly polar basic degradants by on-line hydrogen/deuterium exchange hydrophilic interaction chromatography coupled to tandem mass spectrometry |
| |
Authors: | Min Liu Mike Ronk Da Ren Judy Ostovic Nina Cauchon Zhaohui Sunny Zhou Janet Cheetham |
| |
Affiliation: | 1. Analytical Research & Development, Amgen, One Amgen Center Drive, Thousand Oaks, CA 91320, USA;2. Formulation & Analytical Resources Department, Amgen, One Amgen Center Drive, Thousand Oaks, CA 91320, USA;3. Department of Chemistry & Chemical Biology, Northeastern University, 360 Huntington Ave., Boston, MA 02115, USA |
| |
Abstract: | A hydrophilic interaction liquid chromatography (HILIC) method was used to separate a commonly used pharmaceutical starting material, 4-aminomethylpyridine (4-AMP), and its degradants. The structures of the major degradants were characterized and elucidated without prior isolation by accurate mass measurement, MS/MS analysis and on-line hydrogen/deuterium (H/D) exchange experiments. The mass spectra obtained from H/D exchange experiments are particularly useful to differentiate structural isomers, to elucidate the fragmentation pathways, and to aid in structure elucidation in the absence of MS/MS fragmentation information. The impact of deuterium oxide and temperature on HILIC separation has also been explored here. The integration of H/D exchange with HILIC has been described here for the first time and has been demonstrated to be a powerful structure elucidation tool via the study of degradants in 4-AMP. |
| |
Keywords: | Hydrophilic interaction liquid chromatography (HILIC) Polar and basic compound 4-Aminomethylpyridine Degradant Hydrogen/deuterium exchange Mass spectrometry Structure elucidation |