Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography
Authors:Yi Yang  Dongyu Gu  Haji Akber Aisa  Yoichiro Ito
Institution:1. Bioseparation Technology Laboratory, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10, Room 8N230, Bethesda, MD 20892-1762, USA;2. Key Laboratory of Chemistry of Plant Resources in Arid Regions, Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi 830011, China
Abstract:The performance of type-I high-speed counter-current chromatography was evaluated by changing the column inclination against the rotating centrifugal force field. The separations were performed with two different solvent systems composed of 1-butanol–acetic acid–water (4.75:0.25:5, v/v) (BAW) and hexane–ethyl acetate–methanol–0.1 M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acid as test samples, respectively. A set of short coiled columns connected in series is mounted around the holder hub in two different ways: in the parallel orientation, all column units are arranged in parallel to each other and mounted on the holder at various angles against the horizontal plane. In the zigzag configuration, the neighboring units of the same column are mounted symmetrically forming various angles apart. In the parallel configuration, for both the BAW and HEMW systems, Sf (the retention of stationary phase) first increased as the column angle decreased from 90° to 60° and then decreased, as the column angle further decreased from 60° to 0°, while Rs (peak resolution) continually declined over the entire column angle range from 90° to 0°. But, for both solvent systems, with the zigzag configuration, retention of stationary phase and resolution both decreased as the column angle decreased from 90° to 0°. In general, Sf and Rs for separation of dipeptides in the BAW system, from 90° to 15°, is better for the parallel orientation than for the zigzag configuration. However, at 0°, Sf and Rs are better for the zigzag orientation. In the DNP-amino acid separation with the HEMW system, retention of the stationary phase and Rs for the parallel orientation is better than that for the zigzag orientation from 90° to 30°, whereas from 30° to 0° the results are opposite. Over all results of our studies revealed that the formally used column orientation 5] at 90° inclination yields the highest peak resolution in both solvent systems.
Keywords:Type-I counter-current chromatography  Coil planet centrifuge  The angle against the rotating centrifugal force field  Retention of the stationary phase  Resolution  Dipeptide  DNP-amino acid
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号