Studies on the effect of column angle in centrifugal helix counter-current chromatography
Authors:Yi Yang  Dongyu Gu  Haji Akber Aisa  Yoichiro Ito
Affiliation:1. Bioseparation Technology Laboratory, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10, Room 8N230, Bethesda, MD 20892, USA;2. Xinjiang Key Laboratory of Plant Resources and Natural Products Chemistry, Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi 830011, China;3. Graduate University of the Chinese Academy of Sciences, Beijing 100049, China
Abstract:The performance of the coiled column of centrifugal counter-current chromatography was investigated by changing the angle between column axis and centrifugal force in the separation of dipeptides or DNP-amino acids each with suitable two-phase solvent systems. In general, retention of the stationary phase (Sf) decreased, and peak resolution (Rs) increased as the column angle was increased. The first series of experiments was performed using a polar two-phase solvent system composed of 1-butanol–acetic acid–water (4:1:5, v/v/v) to separate two dipeptide samples, Trp-Tyr and Val-Tyr, at a flow rate of 1 ml/min at 1000 rpm. When the column angle was changed from 0° to 90°, Rs increased from 1.05 (Sf = 60.1%) to 1.17 (Sf = 38.7%) with the lower phase mobile and from 1.02 (Sf = 67.8%) to 1.14 (Sf = 47.4%) with the upper phase mobile, respectively. The second series of experiments was similarly performed with a more hydrophobic two-phase solvent system composed of hexane–ethyl acetate–methanol–0.1 M hydrochloric acid (1:1:1:1, v/v/v/v) to separate three DNP-amino acids, DNP-glu, DNP-β-ala and DNP-ala, at a flow rate of 1 ml/min at 1000 rpm. When the column angle was changed from 0° to 90°, Rs increased from 1.38 (1st peak/2nd peak) and 1.20 (2nd peak/3rd peak) (Sf = 61.1%) to 1.66 and 1.45 (Sf = 34.4%) with the lower phase mobile and from 1.14 and 0.63 (Sf = 72.2%) to 1.53 and 0.87 (Sf = 51.1%) with the upper phase mobile, respectively. The overall results of our studies indicate that increasing the column angle against the radially acting centrifugal force enhances the mixing of two phases in the column to improve the peak while decreasing the stationary phase retention by interrupting the laminar flow of the mobile phase.
Keywords:Centrifugal counter-current chromatography   Angle between column axis and centrifugal force   Retention of the stationary phase   Resolution   Dipeptide   DNP-amino acid
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号