Analysis of low Z elements on Si wafer surfaces with synchrotron radiation induced total reflection X-ray fluorescence at SSRL, Beamline 3-3: comparison of droplets with spin coated wafers
Authors:C Streli  G Pepponi  P Wobrauschek  N Zger  P Pianetta  K Baur  S Pahlke  L Fabry  C Mantler  B Kanngießer  W Malzer
Institution:

a Atominstitut der Österr. Universitäten, Stadionallee 2, Wien 1020, Austria

b Stanford Synchrotron Radiation Laboratory (SSRL), CA, USA

c Wacker Siltronic AG, Burghausen D-84479, Germany

d Inst. f. Atomare Physik und Fachdidaktik, Techn. Univ. Berlin, Berlin 10623, Germany

Abstract:The unique properties of synchrotron radiation, such as high incident flux combined with low divergence, its linear polarization and energy tunability, make it an ideal excitation source for total reflection X-ray fluorescence (TXRF) spectroscopy in order to non-destructively detect trace impurities of transition metals on Si wafer surfaces. When used with a detector suitable for the determination of low energy radiation this technique can be extended to the detection of low-Z elements, such as Al, Na and Mg. Experiments have been performed at SSRL Beamline 3-3, a bending magnet beamline using monochromatic radiation from a double multilayer monochromator. The wafer was mounted vertically in front of the detector, which was aligned along the linear polarization vector of the incoming synchrotron radiation. This configuration allows the detector to accept a large solid angle as well as to take advantage of the reduced scattered X-ray intensity emitted in the direction of the linear polarization vector. A comparison between droplet samples and spin coated samples was done, in order to compare the capabilities of vapor phase decomposition (VPD-TXRF) with conventional SR-straight-TXRF. Detection limits in the range of 50 fg corresponding to 2E10 atoms/cm2 have been obtained for Na. The spin coated samples, prepared from solutions containing an equal amount of Na, Mg and Al showed an unexpected result when performing a scan of the angle of incidence of the incoming X-rays suggesting a different adsorption behavior of the elements in a multielement solution on the wafer surface. The observation of this behavior is important because the spin coating technique is the standard method for the preparation of surface standards in semiconductor quality control. This effect could be characteristic of the Na, Mg, Al solution used, but the angle dependence of the fluorescence signal of a standard should always be investigated before using the standard for calibration of the apparatus and quantification.
Keywords:Total reflection X-ray fluorescence  Synchrotron radiation  Si wafer  Low Z elements
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号