首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Ultra high performance liquid chromatography tandem mass spectrometric detection of glucuronides resistant to enzymatic hydrolysis: Implications to doping control analysis
Authors:Aristotelis Kotronoulas  Josep Marcos  Jordi Segura  Rosa Ventura  Jesús Joglar  Oscar J Pozo
Institution:1. Bioanalysis Research Group, IMIM, Hospital del Mar, Doctor Aiguader 88, Barcelona 08003, Spain;2. Department of Biological Chemistry and Molecular Modelling, Institute of Advanced Chemistry of Catalonia, Spanish Council for Scientific Research (IQAC-CSIC), Jordi Girona 18-26, Barcelona 08034, Spain;3. Department of Experimental and Health Sciences, Universitat Pompeu Fabra, Doctor Aiguader 88, Barcelona 08003, Spain
Abstract:Controversial results have been reported in the literature regarding the behavior of two testosterone (T) metabolites (3α-glucuronide-6β-hydroxyandrosterone and 3α-glucuronide-6β-hydroxyetiocholanolone) excreted after T administration. Due to their potential as biomarkers of T misuse, a UHPLC–MS/MS method for the direct quantification of these glucuronides was developed and validated. In addition, the main phase II metabolites of T that compose the steroid profile used for doping control purposes (glucuronides of T, epitestosterone, androsterone and etiocholanolone) were included. The method was found to be linear and with suitable LODs and LOQs for all metabolites. The average accuracies were between 86% and 120%, the RSDs for the intra- and inter-day precision were below 15% and 25% respectively. The method showed low matrix effect. Samples obtained before and after the administration of T were analyzed by both the developed UHPLC–MS/MS method and the GC–MS/MS method currently used by anti-doping laboratories. Relevant disagreements between the results obtained for 3α-glucuronide-6β-hydroxyandrosterone and 3α-glucuronide-6β-hydroxyetiocholanolone quantitation were observed. These markers seemed to be more suitable for the screening of T misuse when detected by UHPLC–MS/MS. These discrepancies were further investigated in 50 urine samples from healthy volunteers. The two methods gave highly correlated results for all metabolites that are currently included in the athlete's steroid profile confirming the reliability of the UHPLC–MS/MS method. However, the quantification of 3α-glucuronide-6β-hydroxyandrosterone and 3α-glucuronide-6β-hydroxyetiocholanolone, was only possible by using the UHPLC–MS/MS method since three interfering compounds were observed when performing the GC–MS/MS analysis with the most intense ion transitions. These results confirm the potential of the resistant glucuronides as biomarkers of T misuse. Additionally, they suggest that previously reported reference ranges for these metabolites should be reevaluated.
Keywords:Doping control analysis  Steroids  Quantification  Mass spectrometry  Glucuronides
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号