Sensitive determination of four camptothecins by solid-phase microextraction-HPLC based on a boronic acid contained polymer monolithic layer
Authors:Jishun Chen  Xinwen MinPeng Li  Wu ChenDawei Tian  Qinhua Chen
Institution:Affiliated Dongfeng Hospital, Hubei University of Medicine, Hubei 442008, China
Abstract:Camptothecin (CPT) and its derivative have been revealed to possess special anti-cancer activity, extraction methods are necessary for trace determination of CPTs in complex samples. In this work, we prepared a high efficient boronic acid-based polymer monolithic layer for microextraction of CPTs. A disposable membrane filter-based extraction device was developed, and boronic acid groups were co-polymerized into a polyporous polymer skeleton and served as the monolithic sorbent. The prepared poly(4-VB-MA-TRIM) showed good stability and great extraction efficiency toward four CPTs. After optimization of extraction conditions, poly(4-VB-MA-TRIM)-based solid-phase microextraction was coupled HPLC for determination of CPTs in biological samples. The method exhibited low limits of detection of 0.05–0.2 ng mL−1, which is significantly more sensitive than reported HPLC methods. The method also showed wide linear range (0.1–100 and 0.5–200 ng mL−1), good linearity (R2 ≥ 0.9981) and good reproducibility (RSD ≤3.76%). The method has been applied in plasma samples, with good selectivity and good recoveries ranging from 85.1 to 104.7%.
Keywords:Camptothecin  Boronic acid  Solid-phase microextraction  Plasma  HPLC