首页 | 本学科首页   官方微博 | 高级检索  
     


Highly selective and sensitive paper-based colorimetric sensor using thiosulfate catalytic etching of silver nanoplates for trace determination of copper ions
Authors:Sudkate Chaiyo  Weena Siangproh  Amara Apilux  Orawon Chailapakul
Affiliation:1. Electrochemistry and Optical Spectroscopy Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand;2. Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattanna, Bangkok 10110, Thailand;3. Center for Innovation Development and Technology Transfer, Faculty of Medical Technology, Mahidol University, 999 Phuttamonthon 4 Road, Salaya, Nakhon Pathom 73170, Thailand;4. Center for Petroleum, Petrochemicals and Advanced Materials, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand
Abstract:A novel, highly selective and sensitive paper-based colorimetric sensor for trace determination of copper (Cu2+) ions was developed. The measurement is based on the catalytic etching of silver nanoplates (AgNPls) by thiosulfate (S2O32−). Upon the addition of Cu2+ to the ammonium buffer at pH 11, the absorption peak intensity of AuNPls/S2O32− at 522 nm decreased and the pinkish violet AuNPls became clear in color as visible to the naked eye. This assay provides highly sensitive and selective detection of Cu2+ over other metal ions (K+, Cr3+, Cd2+, Zn2+, As3+, Mn2+, Co2+, Pb2+, Al3+, Ni2+, Fe3+, Mg2+, Hg2+ and Bi3+). A paper-based colorimetric sensor was then developed for the simple and rapid determination of Cu2+ using the catalytic etching of AgNPls. Under optimized conditions, the modified AgNPls coated at the test zone of the devices immediately changes in color in the presence of Cu2+. The limit of detection (LOD) was found to be 1.0 ng mL−1 by visual detection. For semi-quantitative measurement with image processing, the method detected Cu2+ in the range of 0.5–200 ng mL−1(R2 = 0.9974) with an LOD of 0.3 ng mL−1. The proposed method was successfully applied to detect Cu2+ in the wide range of real samples including water, food, and blood. The results were in good agreement according to a paired t-test with results from inductively coupled plasma-optical emission spectrometry (ICP-OES).
Keywords:Copper ions   Colorimetric detection   Paper-based sensor   Silver nanoplates   Thiosulfate
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号