首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Chemically selective polymer substrate based direct isotope dilution alpha spectrometry of Pu
Authors:Sumana Paul  Ashok K Pandey  RV Shah  SK Aggarwal
Institution:1. Fuel Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India;2. Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India
Abstract:Quantification of actinides in the complex environmental, biological, process and waste streams samples requires multiple steps like selective preconcentration and matrix elimination, solid source preparations generally by evaporation or electrodeposition, and finally alpha spectrometry. To minimize the sample manipulation steps, a membrane based isotope dilution alpha spectrometry method was developed for the determination of plutonium concentrations in the complex aqueous solutions. The advantages of this method are that it is Pu(IV) selective at 3 M HNO3, high preconcentration factor can be achieved, and obviates the need of solid source preparation. For this, a thin phosphate-sulfate bifunctional polymer layer was anchored on the surface of microporous poly(ethersulfone) membrane by UV induced surface grafting. The thickness of the bifunctional layer on one surface of the poly(ethersulfone) membrane was optimized. The thickness, physical and chemical structures of the bifunctional layer were studied by secondary ionization mass spectrometry (SIMS), scanning electron microscopy (SEM) and SEM-EDS (energy-dispersive spectroscopy). The optimized membrane was used for preconcentration of Pu(IV) from aqueous solutions having 3-4 M HNO3, followed by direct quantification of the preconcentrated Pu(IV) by isotope dilution alpha spectrometry using 238Pu spike. The chemical recovery efficiency of Pu(IV) was found to be 86 ± 3% below Pu(IV) loading capacity (1.08 μg in 2 × 1 cm2) of the membrane sample. The experiments with single representative actinides indicated that Am(III) did not sorb to significant extent (7%) but U(VI) sorbed with 78 ± 3% efficiency from the solutions having 3 M HNO3 concentration. However, Pu(IV) chemical recovery in the membrane remained unaffected from the solution containing 1:1000 wt. proportion of Pu(IV) to U(VI). Pu concentrations in the (U, Pu)C samples and in the irradiated fuel dissolver solutions were determined. The results thus obtained were found to be in good agreement with those obtained by conventional alpha spectrometry, biamperometry and thermal ionization mass spectrometry.
Keywords:Plutonium(IV) selective  Membrane  Surface grafting  Alpha spectrometry  Isotope dilution  Dissolver solutions
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号