Matrix Isopotential Synchronous Fluorescence Spectroscopy for Direct Determination of 1-Hydroxypyrene as a Urinary Biomarker of Exposure to Polycyclic Aromatic Hydrocarbons |
| |
Authors: | LI Yao-Qun SUI Wei WU Chun YU Li-Jun |
| |
Institution: | The Key Laboratory of Analytical Sciences ofMOE and Department of Chemistry, Xiamen University, Xiamen 361005 |
| |
Abstract: | Polycyclic aromatic hydrocarbons (PAHs) are present ubiquitously in the environment and exposure to PAHs is a major environmental and occupational health problem. One important approach in assessing human exposure to PAHs is to measure 1-hydroxypyrene excreted in urine. Its present analytical methods require either chromatographic separation1] or solvent extracting2]. Matrix isopotential synchronous fluorescence spectroscopy (MISFS) is a new fluorimetric technique which consists of performing synchronous scans through a trajectory joining points of equal intensity on a total fluorescence spectrum3]. The technique is very useful for resolving highly-spectrally-overlapped mixtures or detecting analytes in complex fluorescent background without the need for tedious prior separation. |
| |