首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simultaneous detection and quantification of DNA and protein biomarkers in spectrum of cardiovascular diseases in a microfluidic microbead chip
Authors:Dinter  Franziska  Burdukiewicz  Michał  Schierack  Peter  Lehmann  Werner  Nestler  Jörg  Dame  Gregory  Rödiger  Stefan
Institution:1.Brandenburg University of Technology Cottbus—Senftenberg, Universitätsplatz 1, 01968, Senftenberg, Germany
;2.Faculty of Mathematics and Informations Science, Warsaw University of Technology, plac Politechniki 1, 00-661, Warsaw, Poland
;3.attomol GmbH, Schulweg 6, 03205, Bronkow, Germany
;4.BiFlow Systems GmbH, Technologie-Campus 1, 09126, Chemnitz, Germany
;5.Institute of Microbiology and Virology—Brandenburg Medical School Theodor Fontane, Universitätsplatz 1, 01968, Senftenberg, Germany
;6.Faculty of Health Sciences, joint Faculty of the Brandenburg University of Technology Cottbus – Senftenberg, the Brandenburg Medical School Theodor Fontane and the University of Potsdam, Berlin, Germany
;
Abstract:

The rapid and simultaneous detection of DNA and protein biomarkers is necessary to detect the outbreak of a disease or to monitor a disease. For example, cardiovascular diseases are a major cause of adult mortality worldwide. We have developed a rapidly adaptable platform to assess biomarkers using a microfluidic technology. Our model mimics autoantibodies against three proteins, C-reactive protein (CRP), brain natriuretic peptide (BNP), and low-density lipoprotein (LDL). Cell-free mitochondrial DNA (cfmDNA) and DNA controls are detected via fluorescence probes. The biomarkers are covalently bound on the surface of size- (11–15 μm) and dual-color encoded microbeads and immobilized as planar layer in a microfluidic chip flow cell. Binding events of target molecules were analyzed by fluorescence measurements with a fully automatized fluorescence microscope (end-point and real-time) developed in house. The model system was optimized for buffers and immobilization strategies of the microbeads to enable the simultaneous detection of protein and DNA biomarkers. All prime target molecules (anti-CRP, anti-BNP, anti-LDL, cfmDNA) and the controls were successfully detected both in independent reactions and simultaneously. In addition, the biomarkers could also be detected in spiked human serum in a similar way as in the optimized buffer system. The detection limit specified by the manufacturer is reduced by at least a factor of five for each biomarker as a result of the antibody detection and kinetic experiments indicate that nearly 50 % of the fluorescence intensity is achieved within 7 min. For rapid data inspection, we have developed the open source software digilogger, which can be applied for data evaluation and visualization.

 loading=

Graphical abstract

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号