首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of low-LET radiations on CR-39 track detector
Authors:K. Oda   K. Yoshida  T. YamauchiY. Honda   T. Ikeda  S. Tagawa
Affiliation:

Department of Nuclear Engineering, Kobe University of Mercantile Marine, 5-1-1 Fukaeminamimachi, Higashinada-ku, Kobe 658, Japan

The Institute for Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567, Japan

Abstract:The effects of Co-60 gamma-rays and about 25-MeV pulsed electrons have been investigated on CR-39 plastic nuclear track detector. The bulk etch rate was measured as a function of the absorbed dose under three different irradiation conditions; gamma-ray exposure in air at the dose rate of 6 kGy/h, that in vacuum and electron shower in air at 126 kGy/h on average. It was found that the bulk etch rate (V) increased nearly exponentially with the dose (D); V=V0exp(kD), and the characteristic parameter (k) was 35, 9 and 12 MGy−1, respectively. It is considered that a lack of oxygen in damage formation processes could occur momentarily during a short electron pulse, just similarly to the vacuum effect of reduction in track etch rates in outgassed CR-39 plastic.
Keywords:Cr-39   low-LET radiation   gamma-ray   pulsed electron   absorbed dose   bulk etch rate   vacuum effect   radiation damage   high dose rate   optical absorption