首页 | 本学科首页   官方微博 | 高级检索  
     检索      

关于再定时对于E1时钟传送性能影响的测试及分析
引用本文:于天泽,程华,于佳亮.关于再定时对于E1时钟传送性能影响的测试及分析[J].电信工程技术与标准化,2013(9):64-67.
作者姓名:于天泽  程华  于佳亮
作者单位:1. 中国铁路通信信号集团,北京,100166
2. 北京铁路通信技术中心,北京,100038
3. 中国移动通信研究院,北京,100053
摘    要:阐述了SDH的E1支路"再定时"功能,指出目前业内基本不采用的现实情况,并通过实际测试验证"再定时"对于提高时钟信号质量的效果,详细介绍了测试的步骤和方法,并提出明确的建议。

关 键 词:SDH  时钟同步  再定时  测试

About retiming clock for E1 transmission performance impact of testing and analysis
YU Tian-ze , CHENG Hua , YU Jia-liang.About retiming clock for E1 transmission performance impact of testing and analysis[J].Telecom Engineering Technics and Standardization,2013(9):64-67.
Authors:YU Tian-ze  CHENG Hua  YU Jia-liang
Institution:1 Infrastructure Department of China Railway Signal and Communications Corporation, Beijin 100166, China; 2 Senior Engineer of Beijing Railway Communications Technology Center, Beijing 100038, China; 3 China Mobile Research Institute, Beijing 100053, China)
Abstract:Elaborated on SDH E1 tributary "retiming" feature, reality, and through the actual test validation "re-timed' detailing the testing procedures and methods, and make basically do not use the industry that the current to improve the quality of the clock signal effect, clear recommendations.
Keywords:SDH  clock synchronization  retiming  test
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号