Screening method for polycyclic aromatic hydrocarbons in soil using hollow fiber membrane solvent microextraction |
| |
Authors: | King Stephanie Meyer Jill S Andrews Anthony R J |
| |
Institution: | Department of Chemistry and Biochemistry, Ohio University, Athens, OH 45701-2979, USA. sk352800@ohio.edu |
| |
Abstract: | A fast, inexpensive screening method for polycyclic aromatic hydrocarbons in soil has been developed. Using hollow fiber membrane solvent microextraction, 8 microl of octane extraction solvent was placed inside a porous, polypropylene fiber. Following an 8 min analyte preconcentration step, 4 microl of extract was injected into a gas chromatograph. Separation was achieved in less than 10 min with a detection limit of 0.13 mg/kg for 2-methylnaphthalene. Results of both spiked and real soil samples are presented. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|