摘    要:The electrochemical characteristics of multi-component phenolic pollutants, such as phenol (Ph), hydroquinone (HQ) and 4-nitrophenol (4-NP), were investigated on boron-doped diamond (BDD) film electrode by differential pulse voltammetry (DPV) technique. A simple and feasible platform was accordingly established for the direct and simultaneous determination of these three phenolic pollutants. Results showed that, Ph, HQ and 4-NP gave obvious oxidation peaks on BDD electrode at the potential of 1.24, 0.76 and 1.52 V, respectively. Each of them displayed good linear relationship between their oxidation peak currents and their corresponding concentrations in a rather wide range coexisting with one or two of the other phenolic pollutants. The detection limits of Ph, HQ and 4-NP were estimated to be as low as 1.82×10^-6, 1.67×10^-6 and 1.44×10^-6 mol·L^-1, respectively. Therefore, a promising direct and simultaneous electrochemical determination method of multi-component phenolic pollutants in wastewater samples was constructed successfully on BDD electrode with advantages being rapid, simple, convenient, sensitive, in situ and inexpensive.

关 键 词:金刚石薄膜电极 硼掺杂 酚污染物质 微分脉冲伏安法 同时测量 硝基酚 对苯二酚 苯酚
修稿时间:2007-02-06

Direct and Simultaneous Determination of Phenol, Hydroquinone and Nitrophenol at Boron-Doped Diamond Film Electrode
ZHAO, Guo-Hua TANG, Yi-Ting LIU, Mei-Chuan LEI, Yan-Zhu XIAO, Xiao-E. Direct and Simultaneous Determination of Phenol, Hydroquinone and Nitrophenol at Boron-Doped Diamond Film Electrode[J]. Chinese Journal of Chemistry, 2007, 25(10): 1445-1450. DOI: 10.1002/cjoc.200790267
Authors:ZHAO   Guo-Hua TANG   Yi-Ting LIU   Mei-Chuan LEI   Yan-Zhu XIAO   Xiao-E
Affiliation:Department of Chemistry, Tongji University, Shanghai 200092, China
Abstract:The electrochemical characteristics of multi‐component phenolic pollutants, such as phenol (Ph), hydroquinone (HQ) and 4‐nitrophenol (4‐NP), were investigated on boron‐doped diamond (BDD) film electrode by differential pulse voltammetry (DPV) technique. A simple and feasible platform was accordingly established for the direct and simultaneous determination of these three phenolic pollutants. Results showed that, Ph, HQ and 4‐NP gave obvious oxidation peaks on BDD electrode at the potential of 1.24, 0.76 and 1.52 V, respectively. Each of them displayed good linear relationship between their oxidation peak currents and their corresponding concentrations in a rather wide range coexisting with one or two of the other phenolic pollutants. The detection limits of Ph, HQ and 4‐NP were estimated to be as low as 1.82×10?6, 1.67×10?6 and 1.44×10?6 mol·L?1, respectively. Therefore, a promising direct and simultaneous electrochemical determination method of multi‐component phenolic pollutants in wastewater samples was constructed successfully on BDD electrode with advantages being rapid, simple, convenient, sensitive, in situ and inexpensive.