首页 | 本学科首页   官方微博 | 高级检索  
     

Determination of Some Trace Metals in Environmental Samples by Flame AAS Following Solid Phase Extraction with Amberlite XAD-2000 Resin after Complexing with 8-Hydroxyquinoline
引用本文:DURAN Celal,SENTURK H. Basri,GUNDOGDU Ali,BULUT V. Numan,ElCi Latif,SOYLAK Mustafa,TUFEKCI Mehmet,UYGUR Yaprak. Determination of Some Trace Metals in Environmental Samples by Flame AAS Following Solid Phase Extraction with Amberlite XAD-2000 Resin after Complexing with 8-Hydroxyquinoline[J]. 中国化学, 2007, 25(2): 196-202. DOI: 10.1002/cjoc.200790040
作者姓名:DURAN Celal  SENTURK H. Basri  GUNDOGDU Ali  BULUT V. Numan  ElCi Latif  SOYLAK Mustafa  TUFEKCI Mehmet  UYGUR Yaprak
作者单位:[1]Department of Chemistry, Faculty of Arts & Sciences, Karadeniz Technical University, 61080 Trabzon, Turkey [2]Department of Chemistry, Giresun Faculty of Arts & Sciences, Karadeniz Technical University, 28049 Giresun, Turkey [3]Department of Chemistry, Faculty of Arts & Sciences, Pamukkale University, 20020 Denizli, Turkey [4]Department of Chemistry, Faculty of Arts & Sciences, Erciyes University, 38039 Kayseri, Turkey
基金项目:Project supported by research grant from Karadeniz Technical University of Turkey.
摘    要:A procedure for preconcentration of Mn(Ⅱ), Fe(Ⅱ), Co(H), Cu(Ⅱ), Cd(Ⅱ), Zn(Ⅱ), Pb(Ⅱ) and Ni(Ⅱ) based on retention of their complexes with 8-hydroxyquinoline (HQ) on Amberlite XAD-2000 resin in a column was proposed for the analysis of environmental samples by flame AAS. Various parameters such as pH, eluent type, volume, concentration, flow rate and volume of sample solution, and matrix interference effect on the retention of the metal ions were investigated. The optimum pHs for the retention of metal complexes in question were about 6 except for Mn^2+ for whose value is 8. The loading capacity of the adsorbent for these metals and their recoveries from the resin under the optimum conditions were in the range 6.82-9.26 mg·g^-1 and 95%-101%, respectively. The enrichment factor was calculated as 100 and the limit of detection was in the range 0.3-2.2 μg·L^-1 (n=20, blank+ 3s). The proposed enrichment method was applied to tap water, stream water and vegetable samples. The validation of the procedure was carried out by analysis of certified reference material and standard addition. The analytes were determined with a relative standard deviation lower than 6% in all samples.

关 键 词:环境化学 微量元素 重金属 水样
收稿时间:2006-08-04
修稿时间:2006-08-042006-10-25

Determination of Some Trace Metals in Environmental Samples by Flame AAS Following Solid Phase Extraction with Amberlite XAD-2000 Resin after Complexing with 8-Hydroxyquinoline
Celal Duran,H. Basri Senturk,Ali Gundogdu,V. Numan Bulut,Latif Elci,Mustafa Soylak,Mehmet Tufekci,Yaprak Uygur. Determination of Some Trace Metals in Environmental Samples by Flame AAS Following Solid Phase Extraction with Amberlite XAD-2000 Resin after Complexing with 8-Hydroxyquinoline[J]. Chinese Journal of Chemistry, 2007, 25(2): 196-202. DOI: 10.1002/cjoc.200790040
Authors:Celal Duran  H. Basri Senturk  Ali Gundogdu  V. Numan Bulut  Latif Elci  Mustafa Soylak  Mehmet Tufekci  Yaprak Uygur
Affiliation:1. Department of Chemistry, Faculty of Arts & Sciences, Karadeniz Technical University, 61080 Trabzon, Turkey;2. Department of Chemistry, Giresun Faculty of Arts & Sciences, Karadeniz Technical University, 28049 Giresun, Turkey;3. 0090‐258‐2125552;4. Department of Chemistry, Faculty of Arts & Sciences, Erciyes University, 38039 Kayseri, Turkey
Abstract:A procedure for preconcentration of Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) based on retention of their complexes with 8‐hydroxyquinoline (HQ) on Amberlite XAD‐2000 resin in a column was proposed for the analysis of environmental samples by flame AAS. Various parameters such as pH, eluent type, volume, concentration, flow rate and volume of sample solution, and matrix interference effect on the retention of the metal ions were investigated. The optimum pHs for the retention of metal complexes in question were about 6 except for Mn2+ for whose value is 8. The loading capacity of the adsorbent for these metals and their recoveries from the resin under the optimum conditions were in the range 6.82–9.26 mg·g?1 and 95%–101%, respectively. The enrichment factor was calculated as 100 and the limit of detection was in the range 0.3–2.2 µg·L?1 (n=20, blank+3s). The proposed enrichment method was applied to tap water, stream water and vegetable samples. The validation of the procedure was carried out by analysis of certified reference material and standard addition. The analytes were determined with a relative standard deviation lower than 6% in all samples.
Keywords:water and vegetable sample   trace metal   preconcentration   amberlite XAD-2000   FAAS   8-hydroxyquinoline
本文献已被 维普 等数据库收录!
点击此处可从《中国化学》浏览原始摘要信息
点击此处可从《中国化学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号