首页 | 本学科首页   官方微博 | 高级检索  
     


An improved highly sensitive method to determine low oxyresveratrol concentrations in rat plasma and its pharmacokinetic application
Authors:Fangzhen Tian  Hongtu Wei  Tanghong Jia  Hua Tian
Affiliation:1. Department of Dermatology, the First People's Hospital of Jining, Jining, China;2. Department of Bone Surgery (Orthopaedics), The First People's Hospital of Jining, Jining, China;3. Health Board of Jinan, Jinan, China;4. Xuzhuang Health Center of Jining, Jining, China
Abstract:Existing methods to determine oxyresveratrol, a trans‐polyphenolic stilbene, lack selectivity, require large plasma sample volumes or have time‐consuming sample preparation and chromatographic isolation. Here an improved highly sensitive liquid chromatography–tandem mass spectrometry method was developed to determine low oxyresveratrol concentrations in rat plasma. The plasma samples were prepared by liquid–liquid extraction with acetoacetate. The analyte s were separated on Venusil hydrophilic interaction chromatography (HILIC) column (2.1 × 50 mm, 5.0 µm) guarded by a HILIC column (4 × 3.0 mm, 5.0 µm). The mobile phase consisted of acetonitrile–water (containing 1 mmol/L ammonium formate) at gradient elution mode with a flow rate of 0.3 mL/min. Resveratrol was used as the internal standard. An electrospray ionization source was applied and operated in the negative multiple reaction monitoring (MRM) mode. Oxyresveratrol and resveratrol were detected on MRM by the transitions from the precursor to the product ion (m/z 243.1 → 175.1 and 227.1 → 143.0). The total running time was 5 min and the retention times of oxyresveratrol and resveratrol were 1.97 and 1.82 min. Chromatograms showed no endogenous interfering peaks with blank samples. The linear calibration curve was obtained over the concentration range of 1–500 ng/mL. The injection volume was 10 μL and the limit of quantification was 1 ng/mL. The extraction recovery varied from 78.2 to 84.3% for low, medium and high quality control samples. At the same time, the intra‐ and inter‐day relative standard deviations were <6.78 and <10.02%, respectively, while the corresponding intra‐ and inter‐day accuracy relative error values fell in the range of 3.75–6.67%. The HPLC‐MS/MS method was successfully applied to a pharmacokinetics study, in which the experimental rats received a single dose of oxyresveratrol (10 mg/kg, intragastric administration). The pharmacokinetic results are presented. Copyright © 2013 John Wiley & Sons, Ltd.
Keywords:oxyresveratrol  LC‐MS/MS  rat plasma  pharmacokinetics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号