首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Validated LC‐MS/MS method for the simultaneous determination of hyperoside and 2′′–O‐galloylhyperin in rat plasma: application to a pharmacokinetic study in rats
Authors:Donghui Zhou  Yuanzhe Jin  Fengchen Yao  Zhiying Duan  Qi Wang  Jing Liu
Institution:Department of Cardiology, The Fourth Affiliated Hospital of China Medical University, Shenyang, Liaoning, China
Abstract:An LC‐MS/MS method was developed for the first time to simultaneously determine hyperoside and 2′′–O‐galloylhyperin, two major components in Pyrola calliantha extract, in rat plasma. Following extraction by one‐step protein precipitation with methanol, the analytes were separated on a Venusil MP‐C18 column within 2 min, using methanol–water–formic acid (50:50:0.1, v/v/v) as the mobile phase at a flow rate of 0.4 mL/min. Detection was performed on electrospray negative ionization mass spectrometry by multiple‐reaction monitoring of the transitions of 2′′–O‐galloylhyperin at m/z 615.1 → 301.0, of hyperoside at m/z 463.1 → 300.1, and of internal standard at m/z 415.1 → 295.1. The limits of quantification were 2 ng/mL for both hyperoside and 2′′–O‐galloylhyperin. The precisions were <13.1%, and the accuracies were between ?9.1 and 5.5% for both compounds. The method was successfully applied in pharmacokinetic studies following intravenous administration of the total flavonoids of P. calliantha extract in rats. Copyright © 2013 John Wiley & Sons, Ltd.
Keywords:hyperoside  2′      O‐galloylhyperin  LC‐MS/MS  simultaneous determination  pharmacokinetic study
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号